Maintenance
CheckShutdownCircuitChart
Note:Thestateofsystemitem(s)thatisboldisbeingcheckedineachscenario.
System
Engine
PTO(Blades)
MotionControlLeversOutcome
Runningidle(1/3
throttle)
Engaged
Bothleversout(neutral
lock)
PTOmustbeginshutdown
within1second;engine
staysrunning.
Stateof
System
System
EngineParkingBrakeMotionControlLeversOutcome
Runningidle(1/3
throttle)
Engaged
Bothleversnotinneutral
Enginemustbeginshutdown
within1second
Stateof
System