INSTALLATION AND START UP
DANGER!
If the mains cable or plug is damaged, it
must be replaced by the manufacturer, its
service agent or similarly qualied persons
in order to avoid SERIOUS INJURY OR
DEATH!
1. The machine should only be connected to the power supply by qualified personnel. The following
safety instructions should be obeyed at all times.
2. Ensure that the electrical requirements stated on the TECHNICAL SPECIFICATIONS and on the
ratings plate located under the drip tray inside the machine match the specifications of the power
supply.
3. Ensure that the domestic electrical supply where the machine is being installed is rated for and
able to provide the power required by the machine. Insufficient power supply, wiring, grounding,
or insulation can result in overheating and possibility of fire.
4. The coffee machine must be connected to an earth grounded electrical outlet that complies with
the regulations in force in the country of installation.
5. Ensure that a circuit breaker engineered for the power consumption of the machine is installed to
protect the electrical supply, as specified on the ratings plate located under the drip tray.
6. Never connect the machine to the power supply via extension cords, plug adapters, or shared
outlets.
Electrical connection checklist
Important:
The manufacturer will not be held liable
for damage to persons, animals or property
resulting from incorrect installation of the
coffee machine.
Machine: Machine: 400Vac 3Ph+N230Vac Ph+N
Brown
Blue
Blue
Grey
Black
Brown
NEUTRAL
NEUTRAL
PHASE
PHASE
PHASE
PHASE
Yellow/Green
Yellow/Green
Supply cable
Supply cable