Global presets — Frequently used I/O configurations may be saved and recalled either
from the front panel, serial, or Ethernet control. This time-saving feature allows I/O
configurations to be set up and stored in memory for future use.
View I/O mode — Users can easily view which inputs and outputs are actively connected.
Front panel configuration port — Enables easy configuration without having to access
rear panel of the matrix switcher.
Front panel security lockout — Prevents unauthorized use in non-secure environments.
In Lock mode, a special button combination is required to operate the switcher from the
front panel controller.
Optional remote control — The optional MKP 2000 and MKP 3000 X-Y Remote Control
Panels provide the flexibility to control the matrix switcher from a remote location.
Rack-mountable 5U (XTP II CrossPoint 1600), 10U (XTP II CrossPoint 3200), or 20U
(XTP II CrossPoint 6400) full rack width metal enclosure.
Internal universal power supply (XTP II CrossPoint 1600 and XTP II CrossPoint 3200) —
The 100-240 VAC, 50/60 Hz, international power supply provides worldwide power
compatibility.
Primary and redundant power supplies — Redundant power supplies (optional for the
XTP II CrossPoint 1600, standard for the XTP II CrossPoint 3200 and XTP II CrossPoint 6400)
are available for continuous, mission-critical applications where power reliability is crucial.
Highly reliable, energy-efficient internal universal power supply
(XTP II CrossPoint 6400) — The single phase 200-240 VAC, 50/60 Hz, international power
supply, with an attached power cable, provides worldwide power compatibility.
NOTE: In North America, the XTP II CrossPoint 6400 plugs into a standard 220 V power
outlet. In other regions, it must be wired into a 200-240 VAC junction box. In either
case, the outlet or junction box must be installed near the equipment and be easily
accessible.
Permanent, rechargeable battery (XTP II CrossPoint 6400) — The matrix switcher has a
rechargeable lithium battery to track time of day when power is disconnected.
WARNING: There is a danger of explosion if the battery is incorrectly replaced. Replace
it only with the same or equivalent type recommended by the manufacturer. Dispose
of used batteries according to the instructions of the manufacturer.
AVERTISSEMENT : Si la pile est mal remplacée, il y a un risque d’explosion.
Remplacez la batterie seulement avec le même type ou un type similaire de pile,
recommandé par le fabricant. Débarrassez-vous des piles utilisées selon les
instructions du fabricant.
ATTENTION:
Non-Extron personnel must not attempt to remove the battery. Doing so voids the
warranty.
Du personnel ne faisant pas partie d’Extron ne doit pas essayer de retirer la
batterie. Cela annulerait la garantie.
XTP II CrossPoint 1600, 3200, and 6400 Switchers • Introduction 9

Table of Contents

Other manuals for Extron electronics XTP II CrossPoint 6400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extron electronics XTP II CrossPoint 6400 and is the answer not in the manual?

Extron electronics XTP II CrossPoint 6400 Specifications

General IconGeneral
BrandExtron electronics
ModelXTP II CrossPoint 6400
CategoryMatrix Switcher
LanguageEnglish

Related product manuals