E145 25 732784 - Rev. A
ENGLISH
Display Advanced Function
Default
Od
DELAY FOR OPENING LEAF (visualised only with the function Mn = 2):
You can set the delay time for starting leaf 2 opening with respect to leaf 1, in
order to avoid overlapping of the two leaves.
Adjustable from
00 to 59 sec, in 1- second steps.
Next the value 59, the viewing changes to minutes and tenths of a second
(separated by a decimal point) and time is adjusted in 10-second steps up to
the maximum value of
1.3
minutes.
e.g.: if the display shows
1.2, the time is 1 min and 20 sec.
02
r1
LEAF 1 DECELERATION:
You can adjust the deceleration space as a percentage of the total travel of
leaf 1.
Adjustable from
00
to 99
%, in 1% steps.
00 = no deceleration
01 = minimum deceleration space
99 = maximum deceleration space
20
r2
LEAF 2 DECELERATION (visualised only with the function Mn = 2):
You can adjust the deceleration space as a percentage of the total travel of
leaf 2.
Adjustable from
00
to 99
%, in 1% steps.
00 = no deceleration
01 = minimum deceleration space
99 = maximum deceleration space
20
PF
PRE-FLASHING:
You can enable/disable the pre-flashing. Pre-flashing duration = 3 sec.
You can choose:
no = disabled
OC = pre-flashing before each movement
CL = pre-flashing before a closing movement
OP = pre-flashing before an opening movement
PA = pre-flashing only at the end of the pause time
no