E145 26 732784 - Rev. A
ENGLISH
Display Advanced Function
Default
Ph
CLOSING PHOTOCELLS:
The intervention of closing photocells causes the reversing of automated
system (opening).
You can choose:
Y = operate the reversal only after the photocells are released
no = operate the reversal immediately
no
Ad
ADMAP FUNCTION:
Allows operation in compliance with French regulation NFP 25/362.
Y = enabled
no = disabled
no
EC
ANTI-CRUSHING SENSITIVITY (visualised only with the function En
=
Y):
Varying this function varies the amount of time after which, in case of obsta-
cle, the board commands reversal of the leaves, or it will command a stop
if the leaves are in the contact point search space (see the parameter
rB).
The fourth consecutive obstacle detected in the same direction and position
will be defined as a contact point and the leaf will stop in that position.
00 = minimum sensitivity (maximum time before reversal)
10 = maximum sensitivity (minimum time before reversal)
05
r8
MECHANICAL STOP SEARCH ANGLE (displayed only if function En =
Y and functions Fc and FA = no or = 02):
You can adjust the contact point search angle within which the board will stop
movement without reversing, if it encounters an obstacle or the contact point.
Adjustable from
0.3
to 20 degrees.
From
0.3 to 9.9 degrees, adjustments are made in 0.1 degree steps.
From
10 to 20 degrees, adjustments are made in 1 degree steps.
4.0
tA
ADDITIONAL OPERATING TIME (displayed only if function En = no and
functions
Fc and FA = no or = 02):
You can add a work time at the end of movement.
Adjustable from
0 to 30 sec in 1 sec steps.
This time is not considered when calculating the deceleration per-
centage.
03