ACSD-38/80 Digital Brushless AC Servo Drive system - Ref.1609
Power connection. Ballast resistor
If the application requires a Ballast resistor with more than 150 W:
Remove the cable joining the terminals Ri and L+.
Install the external resistor between the terminals Re and L+.
Make sure that the resistance (Ohms) of the external ballast resistor is the same as
that of the internal resistor of that module. See the table General characteristics.
Use KV41 to indicate to the drive that an external ballast resistor has been connected.
Power connection. Drive - motor
F. 24 Ballast resistor connection diagram.
F. 25 Motor-drive power connection diagram.
L+
Re
Ri
2.5 mm
2
External Ballast
L+
Re
Ri
ACSD Drive
Internal
Ballast
ACSD Drive
ACSD DRIVE
MOTOR
OUTPUT
CONNECTOR
(located at the bottom
of the module)
FAGOR cables
MPC- 4x1.5+(2x1) ,
MPC- 4x2.5+(2x1) ,
W
U
V
M
3
Holding brake
(option)
24V Released
E
DA
CB
F
MC-23 base
W
U
V
MPC- 4x1.5
MPC- 4x2.5
1
6
5
4
2
MC-20/6 base
At the motor end
Terminals of the power
connector for FKM
synchronous motor
M
3
(6)
(1)
(2)
(5)
(4)
(3)
W
U
V
M
3
(C)
(A)
(B)
(F)
(E)
(D)
W
U
V
3
FKM
FXM
0V Holding
Terminals of the power
connector for FXM
synchronous motor

Related product manuals