Digital Brushless AC Servo Drive system - Ref.1609 ACSD-75/80
Motor not accepted by the drive.
Motor's power voltage is different from that of the drive (e.g.: motor FXM34.40A.E1.000
with MCP-20L drive).
Some of the sine or cosine signals of the encoder has reached a peak level lower than
150 mV.
Contact Fagor Automation.
The drive has not detected the rotor sensor.
Match the selected sensor with the feedback installed.
Contact Fagor Automation.
Communication error when using a SinCos or SinCoder encoder.
Incoherent U, V, W signals when using an incremental I0 encoder.
Contact Fagor Automation.
Contact Fagor Automation.
E.510 Incoherent combination of motor and feedback
E.605 Excessive damping of the analog signals of the motor
feedback.
E.801 Encoder not detected
E.802 Defective encoder
E.803 Encoder not initialized