Please Note ā Warning
Do not handle filter components or adjacent surfaces when pump is operating.
Components will remain hot for a period after filter.
Allow cooling. Use of
PPE's is recommended.
Note: Burner and temperature controls ON/OFF switch must be in OFF position before operation
of filter pump can begin.
7.2 G3840F MODEL
1.
Press filtration pump switch to turn on pump.
Note: With cabinet door open, switch is located at
RH side of drain valve (Refer to Figure
4).
2.
Turn drain handle clockwise.
3.
Pan will drain through strainer basket and microfilter into bucket and will pump back into
pan.
4.
Clear debris from pan and empty crumb catcher.
5.
If pan drain becomes blocked, clear using drain prod.
6.
When debris has been removed from pan, turn valve handle anti-clockwise to close valve.
7.
Allow pan to refill.
8.
If any solid / shortening remains, repeat Step 1.
Please Note
If the G3840X/G3840FX pan has not been refilled until at least the low oil level
indication (Flashing hazard triangle) clears, then the fryer will not light.