Setting of the curve value for start temperature ventilation.
Setting of the curve value for setpoint thermal control.
The day number is a counter increased by the controller each day at midnight by one up to a maximum
of 999. If the day number is 0 it will not change. The Aura 14 then controls without the curve, even if the
bending points have been set.
If a curve is used, the day number is the basis used to calculate the setpoints from the relevant curve. If
a negative day number is set, the Aura 14 will control without using the curve, until the day number is a
positive number. A negative day number is also increased at midnight by one, except the jump from day
–1 to day +1 (a jump of 2).
There are 10 bending points. At a bending point start by entering the day number; the settings at this bending
point apply to this day number.
Readout of the bending points of the curve (maximum 10).
Setting of the day on which the new curve values must apply.
Setting of the curve value (%) for minimum ventilation.
Setting of the curve value (%) for maximum ventilation.