The Aura 14 cannot control central ventilation control. It transmits the calculated
ventilation position to the controller responsible for controlling central air control.
None: No influence on central air control.
Air inlet: The Aura 14 transmits the control value of the total ventilation to the
controller responsible for controlling central ventilation based on the average
(calculated) ventilation of all assigned sections. This control is particularly
suitable for a central air inlet.
Exhaust: The Aura 14 transmits the control value for the total ventilation to the
controller responsible for controlling the central ventilation based on the highest
demand (calculated ventilation) and the greatest debit (measured ventilation
minus calculated ventilation) of the assigned controllers/sections. This control is
particularly suitable for a central air exhaust system. This control must then be
set identically for the central air control and all assigned controllers/sections.
If two fan groups are used, whereby the main ventilation decreases control,
the central ventilation influence is based on the total controllable ventilation
capacity.
Setting of the difference (offset) in the measured temperature compared to the actual
temperature from the sensor.
Setting of the difference (offset) in the measured temperature compared to the actual
temperature from the extra sensor.
Setting of the difference (offset) in the measured temperature compared to the actual
temperature from the thermal temperature sensor.
Setting of the difference (offset) in the measured temperature compared to the actual
temperature from the outside temperature sensor.