PREPARING THE LIQUID SYSTEM
PREPARING THE LIQUID SYSTEM Liquid Fertilizer Applicator A10 / A13 / A18 / A24 Page 62
PREPARING THE LIQUID
SYSTEM
CAUTION: Prevent serious injury or
death
Check the chemical or fertilizer M/SDS for
proper handling instructions.
Toxic chemicals can enter the body by
breathing spray or contact with bare skin.
Do not take a chance with your health and
safety.
IMPORTANT: Do not run the pump dry
- damage may occur.
NOTE: Always turn sump valve off
whenever working on liquid circuit
components to isolate the liquid in the
tank.
The liquid system is equipped with a screen
(A) in its suction line to remove dirt and
impurities.
Clean Strainer Filter
A. Sump Valve
B. Cap
Clean the filter at the start of each day when
the tank is empty or when dirt is detected in
the system.
1. Clear area of bystanders.
2. Close sump valve (A) if there is liquid
in the tank.
3. Relieve any pressure in the liquid
circuit.
4. Remove cap (B) to access the
screen.
5. Use clear water to clean the screen.
IMPORTANT: Do not over tighten the
canister and crack its head.
6. Install the screen in the canister and
tighten by hand.
7. Open the sump valve if there is liquid
in the tank.
A - Screen
A
B