Library for PC Program
2 10 Position Table Control Function
Function Name
Description
FAS_PosTableReadItem
To read items of RAM area in the specific position table
FAS_PosTableWriteItem
To save specific position table to RAM area
FAS_PosTableWriteROM
To save all of position table values to ROM area :
Total 256 PT values are saved.
FAS_PosTableReadROM
To read position table values in ROM area :
Total 256 PT values are read.
FAS_PosTableRunItem
The motor starts to run from the designated position table
in sequence.
FAS_PosTableReadOneItem
To read items of RAM area in the specific one item of position
table
FAS_PosTableWriteOneItem
To save specific item of specific position table to RAM area