Library for PC Program
FAS_MoveStop
To stop the motor
Syntax
int FAS_MoveStop(
BYTE nPortNo,
BYTE iSlaveNo
);
Parameters
nPortNo
Port number of relevant drive.
iSlaveNo
Slave number of relevant drive.
Return Value
FMM_OK : Command has been successfully performed.
FMM_NOT_OPEN : The drive has not been connected yet .
FMM_INVALID_PORT_NUM : There is no nPort in the connected ports .
FMM_INVALID_SLAVE_NUM : There is no drive of iSlaveNo in the relevant port .
Remarks
Example
Refer to ā€˜FAS_MoveSingleAxisAbsPos ’ library.
See Also

Table of Contents