- 70 -
70
Library for PC Program
FAS_GetActualVel
To read the actual velocity of the motor
Syntax
int FAS_GetActualVel(
BYTE nPortNo,
BYTE iSlaveNo,
long* lActVel
);
Parameters
nPortNo
Port number of relevant drive.
iSlaveNo
Slave number of relevant drive.
lActVel
Parameter pointer where the actual velocity value will be saved
Return Value
FMM_OK : Command has been successfully performed.
FMM_NOT_OPEN : The drive has not been connected yet .
FMM_INVALID_PORT_NUM : There is no nPort in the connected ports .
FMM_INVALID_SLAVE_NUM : There is no drive of iSlaveNo in the relevant port .
Remarks
Example
Refer to ā€˜FAS_GetCOmmandPosition’ library.
See Also

Table of Contents

Related product manuals