FEASA LED ANALYSER
FUNCTIONAL VERSION 
Get Data Mode
getWSI## - Get the Dominant Wavelength, Saturation  & Intensity
Transmit Receive
getwsi##
getwsiall
XXX SSS YYYYY
Where:
## represents the Fiber Number and is a number in the range 1 – 20.
all represents the 20 Fibers in a Feasa 20F, or 3 Fibers in a 3F.
XXX represents the dominant wavelength of the LED in nanometers.
SSS represents the Saturation (whiteness) and is a number in the range 0–100.
YYYYY represents the intensity of the LED.
Description
This command is used to get the value of the Dominant Wavelength for the LED under the
Fiber number  ##. This command should be preceded by the  capture C  command to ensure
valid   LED   data   is   stored   in   the   memory   of   the   LED   Analyser.   The  C1-C5  commands   are
available but are not as accurate.  The data for each LED can be read out one-at-the-time, in
any order.
Alternatively use the getwsiall command to read back the LED data for all 20 leds in
one command.
Example:
The PC transmits  getwsi01  to the LED Analyser to instruct it to send the stored dominant
wavelength & Intensity for the LED positioned under Fiber No 1.   The LED Analyser will return
a string  xxx yyyyy to the PC.
getwsi01
513 100 12345
Back to Index