Manual MWD BP
FEIG ELECTRONIC GmbH Page 40 of 97 MWD BP_Handbuch_mehrsprachig_8.doc
E N G L I S H
16 Convenience Profiles
Profile No.
12 34 5 6789
Channel
I II I II I II I II I II I II I II I II I II
Sensitivity
99 9 9 9 9 999
Direction
appr. appr. appr. appr. appr. appr. appr. appr. appr.
Human
detection
-- -= 3-- -= 3---
Vehicle
detection
- - - - = 4 - - - = 4 - -
Cross traffic
suppression
-- - --= 2- --= 2-
Slow object
tracking
- - - - - - = 2 - - - = 2
Activation
delay
-- - - - - ---
Detection
Dropout
delay
400 ms 400 ms 400 ms 400 ms 400 ms 400 ms 400 ms 400 ms 400 ms
Assignment
(Logic)
XXX XX X XXX
Relay 1
OP/NP
OP OP OP OP OP OP NP NP NP
Assignment
(Logic)
X X X X X XXX
Relay 2
OP/NP
OP OP OP OP OP OP NP NP NP
Comment
Factory
setting:
other
parameter
s such as.
e.g. the
device
address
(=1) are
also reset.
Channel 2
switched
off
Corre-
sponds to
factory
setting,
however
without
resetting
additional
parameters
such as
device
address, ...
Channel
1:
only
persons
(medium)
Channel
2:
only
vehicles
(medium)
Channel 1:
all
Channel 2:
without cross
traffic
(medium)
Channel 1:
all
Channel 2:
with
tracking
slow
objects
(medium)
As for
profile No.
4,
however
NP
As for
profile No.
5,
however
NP
As for
profile No.
6,
however
NP
OP = Open circuit current principle
NP = No-load current principle
appr. = approaching movement