6. Commissioning
28 © Festo Didactic GmbH & Co. KG 
6.3.3 Micro switch (Changer, swivel drive)
The micro switches are used for end stop sensing of the swivel drive (semi-rotary
drive). The micro switches are actuated by adjustable trip cams on the shaft of the
swivel drive.
Prerequisite
Changer module assembled, micro switches pre-assembled.
Rotary drive is tubed up.
Compressed air supply switched on.
Micro switches are wired up
Power supply unit switched on.
Execution
1. Use the manual override of the solenoid valve to place the rotary drive in the
position which you wish to interrogate.
2. Shift the micro switch in the mounting bracket oblong holes until it is actuated.
3. Fix the clamping screws.
4. Start a test run to check if the micro switches are positioned correctly (move
rotary drive to the left/to the right).