6. Commissioning
© Festo Didactic GmbH & Co. KG  43
1. Fill the magazine with a maximum of 8 workpieces. The opening of the
workpieces must point upwards.
2. Check the voltage supply and compressed air supply.
3. Remove workpieces at the transfer points of modules or stations prior to manual
reset.
4. Carry out the reset sequence. The reset sequence is prompted by an illuminated
RESET pushbutton and executed when the pushbutton has been pressed.
5. If a workpiece is present at the transfer point of the stacking magazine, you will
need to remove this manually.
6. Start the sequence of the Distributing station. The Start is prompted by the
illuminated START button and carried out when the pushbutton has been
actuated.
Notes
The sequence can be interrupted at any time by pressing the EMERGENCY-STOP
pushbutton or by pressing the STOP pushbutton.
With the key-operated switch AUTO/MAN, you can select either the continuous
cycle (AUTO) or individual cycle (MAN).
The following applies in the case of a combination of several stations:
The individual stations are reset against the material flow.
The warning light MAG. EMPTY is illuminated if the stacking magazine does not
contain any workpieces. Insert the workpieces and acknowledge by means of
pressing the START button.