2. Parameters of the SPC11 for the DGP(I)(L)-...
2-17
Festo P.BE-SPC11 -DGP-EN en 0012NH
DGP(I)(L)-40-450 to ...-40-600 in horizontal operation
DGP(I)(L)-40-450 DGP(I)(L)-40-500 DGP(I)(L)-40-600
MPYE-5-1/8- H F-010B MPYE-5-1/8- H F-010B MPYE-5-1/4-010B
Mass [kg]
Amplification stage
Cushioning stage
System parameter
Time [s]
Amplification stage
Cushioning stage
System parameter
Time [s]
Amplification stage
Cushioning stage
System parameter
Time [s]
5 16 17 25 0.63 17 17 25 0.68 16 19 23 0.63
10 18 20 25 0.66 19 21 25 0.72 17 22 23 0.62
15 20 23 25 0.71 21 23 25 0.75 19 24 23 0.71
20 21 24 25 0.74 22 25 25 0.76 20 26 23 0.75
25 22 25 25 0.75 23 25 25 0.78 21 26 23 0.70
30 22 26 25 0.77 24 26 25 0.80 21 29 23 0.84
35 23 27 25 0.79 24 28 25 0.82 22 28 23 0.76
40 24 28 25 0.82 25 28 25 0.84 23 29 23 0.76
45 24 29 25 0.82 25 29 25 0.85 23 30 23 0.78
50 25 29 25 0.78 26 30 25 0.87 24 30 23 0.77
55 25 29 25 0.77 26 30 25 0.86 24 32 23 0.86
60 25 32 25 0.87 27 30 25 0.85 24 31 23 0.85
65 26 30 25 0.79 27 30 25 0.84 25 32 23 0.83
70 26 31 25 0.80 27 32 25 0.89 25 34 23 0.91
75 26 32 25 0.86 27 32 25 0.90 25 34 23 0.87