TWINFLEX
®
pro² Control Panel Engineering and Commissioning Manual
3
Contents
Introduction .......................................................................................................................... 5
System Design .......................................................................................................... 5
Equipment Guarantee .............................................................................................. 5
Anti Static Handling Guidelines ................................................................................ 5
Warning .................................................................................................................... 5
EMC .......................................................................................................................... 6
The TWINFLEX®pro² System ............................................................................................. 6
Control Panel ....................................................................................................................... 7
Mounting the Control Panel ...................................................................................... 7
Physical Dimensions ................................................................................................ 7
Power Supply Unit .................................................................................................... 8
General Assembly .................................................................................................... 9
Topology and Cabling ............................................................................................... 9
System Wiring Schematic ......................................................................................... 10
Control Panel Connections ....................................................................................... 11
Overview 2 zone panel.. .............................................................................. 11
Overview 4 / 8 zone panel ........................................................................... 12
USB-B ............................................................................................................. 12
Network: NET A, NET B, SCRN ..................................................................... 12
Monitored Input Wiring .................................................................................... 13
Programmable Inputs 1 & 2 ............................................................................ 13
Twinflex Device Zones Wiring ........................................................................ 14
Conventional Device Zones Wiring ................................................................ 15
Fault Relay ...................................................................................................... 16
Fire Relay........................................................................................................ 16
Mains Input Wiring .......................................................................................... 16
Monitored Outputs 1 & 2 ................................................................................. 17
Auxiliary Power Output ................................................................................... 17
Batteries .......................................................................................................... 18
LCD Contrast .................................................................................................. 18
Write Protect / Write Enable Switch ................................................................ 19
LK1 Buzzer Link ............................................................................................. 19
8 Zone Twinflex Expansion Card .................................................................... 20
8 Zone Conventional Expansion Card ............................................................ 20
General Operation of Control Panel .................................................................................. 21
Control Panel Front ................................................................................................. 21
LED Indication .......................................................................................................... 22
Fire Alarm Controls ................................................................................................... 24
System Controls ....................................................................................................... 24
Access Levels and Codes ........................................................................................ 23
Access Level 1 (Normal) .......................................................................................... 25
Access Level 2A (User) ............................................................................................ 26
Access Level 2B (Supervisor) .................................................................................. 28
Access Level 3 (Engineer) ........................................................................................ 33
Alarm Delays ........................................................................................................................ 56
Alarm Confirmation ............................................................................................................. 57
Introduction .............................................................................................................. 57
Zone Type ................................................................................................................ 57
Zones Normal Operation in Communal Areas. ..................................................... 57
Zones Confirmation Delay for Dwelling Areas. ...................................................... 58
Zones Local or Zonal Alarm Confirmation ............................................................. 58