– 93 –
OPTIONAL
FOR UP TO 30 ADDITIONAL ZONES
(ONE FROM EITHER OR BOTH GROUPS)
ADEMCO 4281 or 5881* Type
RF RECEIVER
WIRELESS ZONES
4281L: UP TO 4
4281M/5881L: UP TO 8
5881M: UP TO 16
4281H/5881H/5881EH: UP TO 30
* 5882 TYPE IN CANADA (See Instructions)
ADEMCO No. 4219
WIRED EXPANSION MODULE
(8 ADD'L EOLR WIRED ZONES)
-OR-
ADEMCO No. 4229
WIRED EXPANSION/RELAY MODULE
(8 ADD'L EOLR WIRED ZONES PLUS 2
OUTPUT RELAYS)
-OR-
ADEMCO No. 4204 RELAY MODULE
(4 OUTPUT RELAYS)
BLK
RED
GRN
YEL
CONNECTION OF THE FIRE ALARM SIGNAL TO A FIRE ALARM
HEADQUARTERS OR A CENTRAL STATION SHALL BE PERMITTED
ONLY WITH THE PERMISSION OF THE LOCAL AUTHORITY HAVING
JURISDICTION. THE BURGLAR ALARM SIGNAL SHALL NOT BE
CONNECTED TO A POLICE EMERGENCY NUMBER.
1234567891011121314151617181920 21
LOCATED AT
LOWER RIGHT
OF CIRCUIT
BOARD
SEE INSTRUCTIONS
FOR PROPER
GROUNDING
TELEPHONE WIRING
(VIA RJ31X* JACK DIRECT
CONNECT CORD)
*IN CANADA, CA38A JACK
DOC LOAD NO.: 3
REMOTE KEYPADS
SYSTEM
MUST
BE
PROGRAMMED WITH AN
FA510KP OR FA550KP. IT NEED
NOT REMAIN IN SYSTEM.
AFTER PROGRAMMING,
THE SYSTEM CAN USE:
FA210KP (30mA),
FA250KP (120mA), OR
FA550KP (140mA).
MULTIPLE
KEYPADS
MAY BE
USED, BUT USE MAX. OF 220 FT.
OF #22 WIRE OR 550 FT. OF #18.
BLACK: KEYPAD GROUND (–) RETURN
RED: KEYPAD PWR (+)
GREEN: DATA IN FROM KEYPAD
YELLOW: DATA OUT TO KEYPAD
REMOTE
KEYPAD
AUX. POWER
OUTPUT
10.5-13.8VDC
500mA MAX.
INTERRUPTS
FOR FIRE
ALARM RESET
NOTE:
KEYPAD
CURRENT
MUST BE
INCLUDED
IN AUX.
CURRENT
DRAIN
CALCULATIONS
}
GEL LEAD ACID TYPE.
BATTERY NORMALLY NEED NOT BE
REPLACED FOR AT LEAST 3 YRS.
BATTERY CAPACITY FOR EMERGENCY
STANDBY USE AT LEAST 4 HOURS.
COMPLIES WITH FCC RULES, PART 68
FCC REGISTRATION NO. AC398U-68192-AL-E
RINGER EQUIVALENCE: 0.7B.
WARNING:
TO PREVENT RISK OF SHOCK,
DISCONNECT TELEPHONE LINE
AT TELCO JACK BEFORE
SERVICING THIS UNIT.
THIS EQUIPMENT SHOULD BE INSTALLED IN
ACCORDANCE WITH THE NATIONAL FIRE
PROTECTION ASSOCIATION'S STANDARD 74
(NATIONAL FIRE PROTECTION ASSOC.,
BATTERYMARCH PARK, QUINCY, MA 02269).
PRINTED INFORMATION DESCRIBING PROPER
INSTALLATION, OPERATION, TESTING,
MAINTENANCE, EVACUATION PLANNING AND
REPAIR SERVICE IS TO BE PROVIDED WITH
THIS EQUIPMENT.
CHARGING
VOLTAGE
13.8VDC
BATTERY
12V, 4AH
(e.g. ADEMCO
No. 467)
OR 12V, 1.2AH
+
+
CONNECTOR TABS
FOR COMPLETE
INFORMATION,
SEE
INSTRUCTIONS
PLUG-IN
TRANSFORMER
16.5VAC, 25VA
(e.g. ADEMCO
No. 1321.
USE No. 1321CN
IN CANADA)
TO 110VAC
UNSWITCHED
OUTLET (24HR)
+
ALARM OUTPUT
10.5-13.8VDC, 2A MAX.
(600mA MAX FOR UL USAGE,
INCLUDING AUX. POWER)
STEADY FOR BURGLARY/PANIC,
PULSING FOR FIRE (e.g. USE
ADEMCO No. 740 SOUNDER,
No.702 OR 719 SIREN, OR 12V BELL)
3A
BLK
RED
GRN
YEL
BLK
RED
GRN
YEL
AND/OR
1000
OHMS
EOLR
1000
OHMS
EOLR
ZONE 5
ZONE 6
HI
LO
HI
LO
WARNING: OWNER'S INSTRUCTION NOTICE NOT TO BE REMOVED. WEEKLY
TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM.
TIP
(BROWN)
RING
(GRAY)
TIP
(GREEN)
RING
(RED)
}
}
INCOMING
PHONE
LINE
HANDSET
BLACK
RED
+
ADEMCO No. 5800TM
TRANSMITTER MODULE
(20mA)
(for No. 5827BD
Wireless Bidirectional Keypad)
AND/OR
FA4285
VOICE MODULE (160mA)
AND/OR
ADEMCO
LONG RANGE RADIO
1000
OHMS
EOLR
1000
OHMS
EOLR
ZONE 1
ZONE 2
HI
LO
HI
LO
1000
OHMS
EOLR
1000
OHMS
EOLR
ZONE 3
ZONE 4
HI
LO
HI
LO
• MAXIMUM LOOP RESISTANCE: (EACH ZONE) 300 OHMS (PLUS EOLR)
• RESPONSE, ZONES 1-6: 300-500MSEC
• ZONE 3 CAN BE PROGRAMMED FOR N.C. SENSOR
FAST RESPONSE TO AN OPEN: 10MSEC MAX
• ZONE 5 CAN BE PROGRAMMED FOR USE AS
A FIRE ZONE. SEE DIAGRAM.
TO DETERMINE TOTAL STANDBY LOAD
ON BATTERY, ADD 100mA TO TOTAL OF
AUX. POWER OUTPUT AND REMOTE
KEYPAD CURRENTS.
USE UL LISTED LIMITED
ENERGY CABLE FOR
ALL CONNECTIONS
BATTERY FUSE
(e.g. ADEMCO No. 90-12)
FOR REPLACEMENT
USE SAME VALUE
AUX PWR
OUTPUT
TERMS
+
-
TO HI SIDE OF SELECTED ZONE
TO LO SIDE OF SELECTED ZONE
+
-
-
+
EOL
POWER
SUPER-
VISION
RELAY
MODULE
A77-716B
5
4
4-WIRE SMOKE
OR COMBUSTION
DETECTOR
2000
OHMS
EOLR
HEAT
DETECTOR
ZONES 2–7
*
+
RED
BLK
*IF PROGRAMMED FOR FIRE
VIOLET
* IF PROGRAMMED FOR FIRE
TO ZONE 5*
SET RECEIVER’S
DIP SWITCH FOR
DEVICE ADDRESS
OF “0”.
See receiver’s
instructions.
SET UNIT’S DIP
SWITCH
FOR DEVICE ADDRESS
OF “1”
See unit’s instructions.
1000
OHMS
EOLR
THESE OPTIONAL ITEMS
MAY ALSO BE USED
SEE THEIR INSTRUCTIONS
EARTH
GROUND
TERMINAL
EARTH
GROUND
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTER-
FERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFER-
ENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE
UNDESIRED OPERATION.
Figure 17. FA142C SUMMARY OF CONNECTIONS DIAGRAM

Table of Contents

Other manuals for First Alert FA142C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the First Alert FA142C and is the answer not in the manual?

First Alert FA142C Specifications

General IconGeneral
BrandFirst Alert
ModelFA142C
CategorySecurity System
LanguageEnglish

Related product manuals