– 86 –
Section 19. SPECIFICATIONS & ACCESSORIES
Specifications
FA142C
SECURITY CONTROL
1. Physical: 12-1/2" W x 14-1/2" H x 3" D (318mm x 368mm x 76mm)
2. Electrical:
VOLTAGE INPUT: 16.5VAC from plug-in 25VA transformer, Ademco No.
1321/TF2 (in U.S.A.)
RECHARGEABLE BACK-UP BATTERY: 12VDC, 4AH (Gel type).
Charging Voltage: 13.8VDC.
ALARM SOUNDER: 12V, 2.0 Amp output can drive 12V BELLS or can
drive one or two 702 (series connected) self-contained 20-watt sirens. Do
not connect two 702s in parallel.
AUXILIARY POWER OUTPUT: 12VDC, 500mA max. Interrupts for 4-wire
smoke detector reset.
Note: For UL installations, Alarm Sounder plus Auxiliary Power currents
should not exceed 600mA total.
STANDBY TIME: (see Table in the
FINAL POWER UP
section)
FUSE: Battery (3A) No. 90–12.
3. Communication:
FORMATS SUPPORTED:
Ademco Express,
10 characters/sec, DTMF (Touch-Tone) Data Tones, 1400/2300Hz ACK,
1400Hz KISSOFF.
Ademco Contact ID Reporting,
10 characters/sec., DTMF (Touch-Tone) Data Tones, 1400/2300Hz ACK,
1400Hz KISSOFF.
Ademco Low Speed, 10 pulses/sec, 1900Hz Data Tone,
1400Hz ACK/KISSOFF.
Radionics/SESCOA, 20 pulses/sec, 1800Hz Data Tone, 2300Hz
ACK/KISSOFF. Can report 0–9, B–F.
Line Seize: Double Pole.
Ringer Equivalence: 0.7B.
FCC Registration No.: AC 398U–68192–AL–E.
4. Maximum Zone Resistance: Zones 1–6 = 300 ohms excluding EOLR.
5. Zone Response: Zones 1–6: 300–500 msec
Zone 3 can be programmed for N.C. sensor fast (10 msec max.) response
to an open
FA210KP
REMOTE KEYPAD
1. Physical: 5-3/4" W x 4-3/4" H x 1" D (146mm x 121mm x 26mm).
2. Electrical: Voltage Input: 12VDC, Current Drain: 30mA.
3. Interface Wiring: To control panel's keypad connection points.
RED: 12VDC input (+) aux power.
GREEN: Data Out to Control.
YELLOW: Data In from Control.
BLACK: Ground.
FA250KP
REMOTE KEYPAD
1. Physical: 5-1/16" W x 6-3/8" H x 1-3/4" D (129mm x 162mm x 45mm).
2. Electrical: Voltage Input: 12VDC.
Current Drain: 120mA.
3. Interface Wiring: Same as FA210KP.

Table of Contents

Other manuals for First Alert FA142C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the First Alert FA142C and is the answer not in the manual?

First Alert FA142C Specifications

General IconGeneral
BrandFirst Alert
ModelFA142C
CategorySecurity System
LanguageEnglish

Related product manuals