Installation Instructions
Page 32 Panda_6000i_System_eng_s01835.book.R01 - Chapter C: Installation Instructions 16.1.09
C.2 Generator connections
Connect all electrical wires within the capsule tightly to the motor and the generator. This is also
the case for fuel lines and cooling water lines.
The electrical connections MUST be carried out according to the respective valid regulati-
ons. This also concerns used cable materials. The cable supplied is meant for laying "pro-
tected" (i.e. in pipe) at a temperature up to a max of. 70°C (160°F). The on-board circuit
must also be fitted with all essential fuses.
ATTENTION! Before working (installation) on the System read the section
„Safety Instructions“ in this Manual.
Fig. C.2-1: Generator connections
Fig. C.2-2: Generator connections
1
2
3
4
5
6
7 8
9
1. Raw water inltake
2. Fuel supply (in)
3. Fuel return line (out)
4. Cable for fuel pump
5. Motor oil drain hose
6. Cable for generator output AC out
7. Cable for iControl panel
8. Passage for starter battery cable (-)
9. Passage for starter battery cable (+)
1
2
3
4
1. Exhaust outlet
2. Connection external ventilation valve
3. Connection from external expansion tank
4. Connection to external expansion tank