Page 82 - Chapter A: Panda iControl Panel_iControl_eng.fm
Fischer Panda Datasheet
A.1 Safety instructions
The generator may not be taken into use with the cover removed.
The rotating parts (belt-pulley, belts, etc) must be covered and protected so that there is no danger to life and
body!
If a sound insulation cover must be produced at the place of installation, then well-placed signs must show that
the generator can only be switched on with a closed capsule.
All servicing-, maintenance or repair work may only be carried out, when the motor is not running.
Electrical power: DANGER TO LIVE!
Electrical voltages above 48 volts (battery chargers greater than 36 volts) are always dangerous
to life). The rules of the respective regional authority must be adhered to. Only an electrician
may carry out installation of the electrical connections for safety reasons.
Before start working at the Panda i-series generator (service, repair ect), diconnect the starter battery (First minus
cable, then positive cable), so that the generator cannot be unintentionally started.
A.2 Connection of the iControl
To connect the iConrol use the original prepared cable.
(6 wires shilded)
Terminator cablecolour 4000i cablecolour 6000i
1. U+ cablecolour brown brown
2. Gnd cablecolour brown-white grey
3. RZL cablecolour green green
4. D_A cablecolour blue white
5. D_B cablecolour blue-white yellow
Between clamp RZL(3) und Gnd(2) an automatik start device (Battery monitor) can be connected
Fig. A.2-1: Connection of the iControl