E.3 Ventilating the fuel system
Normally, the fuel system is designed to ventilate air itself i.e. as soon as the electric starter motor
starts operation the fuel pump starts working and the fuel system will be de-aerated after some
time automatically. It is nevertheless essential to ventilate the system as follows prior to the first
operation (as all hoses are empty):
1. Take off the plug at the solenoid of the
starter motor.
Fig. E.3-1: Starter motor
2. Switch the panel „ON“ (1 = „ON/OFF-
button).
3. Press „START“-button (2). The fuel
pump runs audible.
Fig. E.3-2: iControl panel