Maintenance Instructions
16.1.09 Panda_6000i_System_eng_s01835.book.R01 - Chapter E: Maintenance Instructions Page 67
4. Remove the impeller from the shaft by
means of multi grip pliers..
5. Mark the impeller, to make sure that it
is in the correct position when re-instal-
lation is carried out.
Fig. E.7.3-4: Impeller
6. Check the impeller for damage and
replace it if necessary.
7. The impeller should have been lubrica-
ted with glycerine or with a non-mineral
oil based lubricated e.g. silicone spray,
before re-insertion into the housing.
Attention: This is very important,
because the impeller can quickly be
damaged.
Fig. E.7.3-5: Impeller
8. Attach the impeller to the pump shaft (if
the old impeller is re-used, initially
check the marking).
9. Fastening the cover and use a new
seal.
Fig. E.7.3-6: Cover pump shaft