EasyManua.ls Logo

Flintec FT-112 - Page 153

Flintec FT-112
170 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019 Page 152 of 170
5
Very High
01000001
65
R/
W
Power on zero
(1)
(2)
0
Disable
1
± %2
2
± %2LK
3
± %10
4
+ %15, - %5
5
± %20
01000010
66
R/
W
Zeroing Range
(1)
(2)
0
Disable
1
± 2%
2
± 3%
3
± 20%
4
± 50%
01000011
67
R/
W
Auto Zero
Tracking
(1) (2)
0
Disable
1
± 0,3d
2
± 0,5d
3
± 1d
4
± 2d
5
± 3d
01000100
68
R/
W
Tare
(1) (2)
0
No
1
Multi tare
2
Tare only at gross
3
Preset tare
4
Preset tare at gross
01000101
69
R/
W
Stability
Detection
Range
(1) (2)
0
± 0,3d
1
± 0,5d
2
± 1d
3
± 2d
4
± 3d
5
± 4d
6
Disable
01000110
70
R/
W
Stability Time
(1) (2)
Refer to par. [517] page 64
01000111
71
R/
W
Unit
(1) (2)
0
g
1
kg
2
t
3
lb
4
No unit
5
N
6
kN
7
kLb
01001000
72
R/
W
Range
(1) (2)
0
Single range
1
2 x Multi Range
2
3 x Multi Range
3
2 x Multi Interval
4
3 x Multi Interval
01001001
73
R/
W
Capacity-1
(1) (2)
Refer to par. 523 on page 65
01001010
74
R/
W
Decimal
point-1
(1) (2)
0
XXXXOO
1
XXXXXO
2
XXXXXX
3
XXXXX.X
4
XXXX.XX
5
XXX.XXX
01001011
75
R/
W
Increment-1
(1) (2)
0
X1
1
X2
2
X5
01001100
76
R/
W
Capacity-2
(1) (2)
01001101
77
R/
W
Decimalpoint-2
(1)
(2)
01001110
78
R/
W
Increment-2
(1) (2)