Camera web interface
10
5. In the Action section, select which actions the camera will perform when an alarm is
triggered:
Digital OUT Outputs a digital pulse. Also, type a pulse length (in millisec-
onds) in the Pulse time box.
E-mail Automatically sends the captured Image, Result, or Video to the
recipients defined in Settings > Alarm recipients. For more infor-
mation, see section 10.6.2 Alarm recipients, page 35.
Send to FTP
Automatically sends the captured Image or Video to the FTP
site defined in Settings > Alarm recipients. For more information,
see section 10.6.2 Alarm recipients, page 35.
Save to camera
Automatically saves the captured Image or Video to the memo-
ry of the camera.
During alarm
Temporarily disables the periodic calibration while the image/
video is being captured.
The image/video can later be viewed and managed under the Library tab:
• the captured image frame that triggered the alarm,
• the 5 second video sequence when the alarm was triggered.
6. When completed, click Set alarm. The alarm is now listed under Active alarms.
10.4.2.2 Setting an alarm based on the digital input
To configure an alarm based on the digital input, follow this procedure:
1. In the Active Measurements section, click the plus sign under Add alarm next to the
digital input result to be used for the alarm. The Alarm dialog box appears.
2. In the Alarm label section, type an Alarm name.
3. In the Trigger section and in the Value list; select “0” to trigger the alarm on a low sig-
nal or select “1” to trigger on a high signal.
4. In the Action section, select which actions the camera will perform when an alarm is
triggered:
Digital OUT Outputs a digital pulse. Also, type a pulse length (in millisec-
onds) in the Pulse time box.
E-mail Automatically sends the captured Image, Result, or Video to the
recipients defined in Settings > Alarm recipients. For more infor-
mation, see section 10.6.2 Alarm recipients, page 35.
Send to FTP
Automatically sends the captured Image or Video to the FTP
site defined in Settings > Alarm recipients. For more information,
see section 10.6.2 Alarm recipients, page 35.
Save to camera
Automatically saves the captured Image or Video to the memo-
ry of the camera.
During alarm
Temporarily disables the periodic calibration while the image/
video is being captured.
The image/video can later be viewed and managed under the Library tab:
• the captured image frame that triggered the alarm,
• the 5 second video sequence when the alarm was triggered.
5. When completed, click Set alarm. The alarm is now listed under Active alarms.
#T810409; r. AH/78915/78915; en-US