EasyManuals Logo

FLIR SeaFLIR II Series User Manual

FLIR SeaFLIR II Series
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #40 background imageLoading...
Page #40 background image
26
The NUC process should be repeated whenever the output image
becomes spatially noisy as shown in the left image in Figure 3-5. The
output can become spatially noisy when the environmental temperature
changes (such as from day to night operation and vice versa). NUCs
should be performed to align the sensitivities of the individual pixels as
shown in the right picture. This will enable optimum detection and
recognition.
Figure 3-4. Non-Uniformity Correction (NUC) Display
Figure 3-5. IR Camera Non-Uniformity Correction (NUC)
Commercial in Confidence
Export Level 2
Issued to: AgustaWestland
CM Ref:4049
Valid on Day of Issue only.
Document will not be updated
Uncontrolled : 4256
Retrieval Date:07-Dec-10
Requested by Bower, Richard

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FLIR SeaFLIR II Series and is the answer not in the manual?

FLIR SeaFLIR II Series Specifications

General IconGeneral
BrandFLIR
ModelSeaFLIR II Series
CategoryAll in One Printer
LanguageEnglish

Related product manuals