Specifications
Contact Flow Technical Service for further information. Also
see the system drawings in Chapter 5.
Dimensions
HyperJet94i-S .......... 54in.x40in.x45in.
HyperJet94i-D.......57.4in.x55.3in.x44.1in.
Oil ................................240SSU
Flow recommends the following oils, but other manufac
-
turer’s equivalents can be used:
Shell Turbo T 46
Chevron Turbine Oil GST 46
Mobil DTE Medium
Texaco Regal R&O 46
Reservoir
HyperJet94i-S..............25gallons(95liters)
HyperJet94i-D ............37gallons(140liters)
Outputpressure.............87,000psi(6000 bar)
Filtrationprovided.........0.5micronand1micron
Cooling water in
HyperJet94i-S.......3gpm@50psi,60°Forless
HyperJet94i-D...5gpmmin@50psi,60°Forless
Filtered water in
HyperJet94i-S ....1gpm@30-35psi,80°Forless
HyperJet94i-D....3gpm@30-35psi,80°Forless
Air..................15SCFM@90psi(6.2bar)
Voltage
HyperJet94i-S.........460VAC/125A/60Hz,3ø
HyperJet94i-D ........460VAC/200A/60Hz,3ø