Power Logger
Technical Specifications
51
Technical Specifications
General Information
Display: ¼ VGA Graphic Color transmissive
displays 320 x 240 Pixel with additional
background lighting and adjustable
contrast, text and graphics in color.
Quality: Developed, designed and manufactured
according to DIN ISO 9001
Memory: 4 MB Flash memory, from this 3.5 MB for
measuring data;
Interface: RS 232 SUB-D socket; 115.2 kBaud, 8
data bits, no parity, 1 stop bit, firmware
updates are possible with the RS 232
interface (9-pole extension cable)
Sample rate: 10.24 kHz
Line frequency: 50 Hz or 60 Hz, user-selectable, with
automatic synchronization
Power supply: NiMH battery-pack, with ac adapter (15 V
to 20 V / 0.8 A)
Operation time with battery: Typical > 24 h without backlight
> 12 h with backlight
Dimensions: 240 x 180 x 110 mm (6.1 x 4.6 x 2.8 in)
Weight: 1.7 kg (3.75 lb), including battery
Temperature ranges
Working temperature range: -10 °C to +50 °C
Storage temperature range: -20 °C to +60 °C
Operating temperature range 0 °C to +40 °C
Reference temperature range: +23 °C ± 2 K