Calibration Options
1
1-5
Calibration Options 1-6.
Unless requested at time of order, the 732B is shipped cold (not under battery power)
and will need to be calibrated on receipt. A procedure to calibrate a 732B using a
reference 732B as a transfer standard is provided in Section 5. After calibration, the
732B must be kept powered by ac power or battery, even during shipment. Fluke
calibration services that are available for the 732B are described next.
Note
Contact a Fluke Sales or Service Center for price and delivery information
about 732B calibration options. Addresses for Fluke Service Centers are
provided following the parts lists in Section 6.
732B-000 Special Calibration 1-7.
If you ordered Option 732B-000, the standard is shipped to you hot with a calibration
report that assigns a value to the 10V output. This calibration meets or exceeds the
requirements of MIL-STD-45662A.
732B-100 Special Calibration and Drift Characterization 1-8.
If you ordered Option 732B-100, the standard is shipped to you hot with a calibration
report that assigns a value to the 10V output. This calibration meets or exceeds the
requirements of MIL-STD-45662A. In addition, a calibration report shows the predicted
output on the 1st of each month for the 12 months following shipment.
732B-200 On-Site Calibration 1-9.
Option 732B-200 is the Fluke Direct Volt Maintenance Program, as has been applied to
other Fluke dc standards equipment. This program works as follows:
1. Fluke hot-ships a Fluke-owned transfer standard with all the necessary
interconnecting cables and clear instructions.
2. You make a series of comparisons over five days and send your data to Fluke.
3. Fluke sends you a calibration report that assigns a value to your 732B 10V output
relative to the Fluke Volt. The Fluke Volt is maintained by means of a Josephson
Junction array in the Fluke Primary Standards laboratory. Periodic transfers to NIST
also maintain traceability to the U.S. Legal Volt (at greater uncertainty) for those
who are required to maintain NIST traceability.
Warranty Information 1-10.
The warranty that applies to your Fluke product appears at the front of this manual.