EasyManuals Logo

Fluke 8842A User Manual

Fluke 8842A
269 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
ix
List of Figures
Figure Title Page
1-1. External Dimensions.............................................................................................. 1-11
2-1. Line Voltage Selection Settings............................................................................. 2-2
2-2. Adjusting the Handle ............................................................................................. 2-3
2-3. Rack-Mount Kits.................................................................................................... 2-3
2-4. Installing the Single Rack Mount Kit .................................................................... 2-4
2-5. Front Panel Features .............................................................................................. 2-5
2-6. Rear Panel Features ............................................................................................... 2-7
2-7. Typical Error Messages ......................................................................................... 2-8
2-8. Overrange Indication ............................................................................................. 2-12
2-9. Measuring Voltage and Resistance........................................................................ 2-15
2-10. Measuring Current................................................................................................. 2-15
3-1. IEEE-488 Address Selection.................................................................................. 3-4
3-2. Remote Operation Block Diagram......................................................................... 3-5
3-3. Typical Command String....................................................................................... 3-6
3-4. Commands Which Correspond to the Front Panel................................................. 3-7
3-5. Device-Dependent Command Set.......................................................................... 3-8
3-6. Output Data Format ............................................................................................... 3-10
3-6. Trigger Selection Logic Diagram .......................................................................... 3-18
3-7. Interpretation of Messages..................................................................................... 3-22
3-9. Example Program................................................................................................... 3-33
3-10. Example Program: Taking Readings with Local Control...................................... 3-34
3-11. Example Program: Using the Serial Poll Register................................................. 3-35
3-12. Example Program: Record Errors During Selftest................................................. 3-36
3-13. Example Programs: Using the IBM PC................................................................. 3-37
4-1. Circuit Loading Error Calculation ......................................................................... 4-2
4-2. Measuring Input Bias Current Error ...................................................................... 4-3
4-3. Wire Ohms Measurement...................................................................................... 4-4
4-4. Wire Ohms Measurement...................................................................................... 4-6
4-5. Burden Voltage Error Calculation ......................................................................... 4-9
4-6. Waveform Comparison Chart................................................................................ 4-11
4-7. Typical Crest Factors for Various Waveforms ...................................................... 4-12
4-8. Combined AC and DC Measurement .................................................................... 4-13
4-9. Reduction of Zero-Input Error............................................................................... 4-14
4-10. Shielding for Low Voltage Measurements ............................................................ 4-15
4-11. Shielding for Low Resistance Measurements........................................................ 4-15

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 8842A and is the answer not in the manual?

Fluke 8842A Specifications

General IconGeneral
Maximum Voltage1000 V
Maximum Current2 A
Operating Temperature0°C to 50°C
Weight2.5 kg
DC Voltage Range100mV to 1000V
DC Current Range0 to 2 A
AC Current Range0 to 2 A
Frequency Range20 Hz to 20kHz
Basic Resistance Accuracy0.01%
Dimensions216mm x 88mm x 280mm
Resistance Range200 Ω to 20 MΩ

Related product manuals