DISASSEMBLING THE SCOPEMETER
6-3
4. The bottom cover
aseembly is secured to the top cover with two M3
Torx screws (item
29)
that
are accessible in the
battery compartment. Use a Torx screwdriver
to remove the two screws.
5. Lift the bottom
cover a lithe from the top cover and unfold the
ScopeMeter.
NOTE: Do
not damage the black gaskets and keep them with the front co\/er
and
the
lower case half.
A correctly f/tted gasket assures proper sealing of the
ScopeMeter.
DIG tTAL PRINTED
CIRCUIT BOARD A
1
ANALOG PRI>rTH3
CmCUITBOUnD A2
BOTTOM
COVER
BATTERY
COVER
STAND
Figure 6.2 Opening the
ScopeMeter