Fluke 9190A User Manual

Fluke 9190A
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
January 2013
© 2013 Fluke Corporation. All rights reserved. Specifications are subject to change without notice.
All product names are trademarks of their respective companies.
9190A
Ultra-Cool Drywell
Operators Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Fluke 9190A and is the answer not in the manual?

Fluke 9190A Specifications

General IconGeneral
CategoryMeasuring Instruments
Model9190A
ManufacturerFluke
DisplayLCD
Display Resolution0.01 °C
ControllerMicroprocessor-based
CommunicationRS-232
Frequency Range50/60 Hz
Storage Temperature-20 °C to 60 °C
Accuracy±0.05°C
Power Supply100-240V AC, 50/60Hz
Heating Time15 min to temperature
Operating Temperature40 °C

Summary

Chapter 2 Operation

Introduction and Calibrator Features

Overview of the calibrator's function, features, and front panel components.

Initial Setup and Basic Configuration

Steps for unpacking, connecting power, and configuring basic settings like language, contrast, and security.

Menu System Navigation

Explains the main menu structure and how to use buttons to navigate through options.

Configuring Operational Parameters

Details on configuring temperature, programs, system settings, communications, and preparing probes.

Performing Operations

Procedures for installing/removing inserts, inserting probes, setting temperatures, and executing calibration programs.

Chapter 3 Remote Operation

Introduction and Setup

Explains remote operation via RS-232 and USB, and the necessary setup.

Communication Configuration

Details on configuring baud rate and linefeed for serial and USB communication.

Remote Operation Commands

Overview of command syntax, structures, and categorized command lists for controlling the calibrator.

Chapter 4 Calibration

Temperature Source Calibration

Procedures for calibrating the temperature source, including fundamentals, equipment, and step-by-step instructions.

Input Panel Calibration

Procedures for calibrating the input panel, including terminology, equipment, and test processes.

Chapter 5 Maintenance and Troubleshooting

Product Maintenance

Instructions for cleaning the product, removing moisture, and replacing fuses.

User-Replaceable Parts and Accessories

Lists part numbers for user-replaceable components and accessories.

Troubleshooting Guide

A guide to identifying and resolving common operational problems with the calibrator.