2
-
10
CHARACTERISTICS
CHARACTERISTICS SPECIFICATIONS
ADDITIONAL INFORMATION
AC Voltage
Ranges
300 mV. 3V, 30V, 250V Manual or automatic ranging
on
peak voltage.
High Voltage xIO Probe
extends
measurement to 600V. Peak
voltage is 2.5x range and 375V in
250V range.
Resolution 0.1 mV, 1 mV, 0.01 V.
0.1V Multiply X10 with High Voltage
Probe.
Accuracy (AC Coupled)
Using High Voltage 10:1
Probe
Valid from 5%.. 100% of range.
50 Hz...60 Hz
±(1%+ 10)
20 Hz...20 kHz ±(2%+
15)
5HZ...1 MHz
Accuracy (DC Coupled)
Using High Voltage 10:1
Probe
±
(3% +
20)
50 Hz... 60 Hz
±
(1% +
10)
1 Hz.. .20 kHz
±
(2% +
15)
Crest Factor
Meter prevents crest factor errors
by autoranging on Input waveform
peaks.
Digital Display
3000 counts Up to 4500 counts,
at 260V range: 2500.
Display Update c 300 ms
Response Time
@ Input freq
>50
Hz
<
3.5s
SMOOTH < 10s
FAST < Is
DC Common Mods
Rejection Ratio
> 100 dB
@ dc
>
100 dB @
50, 60.
or 400 Hz
AC Common
Mode
Rejection
Ratio >60d6 @ dc..60Hz