EasyManuals Logo

Fluke 93 User Manual

Fluke 93
267 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
2
-
10
CHARACTERISTICS
CHARACTERISTICS SPECIFICATIONS
ADDITIONAL INFORMATION
AC Voltage
Ranges
300 mV. 3V, 30V, 250V Manual or automatic ranging
on
peak voltage.
High Voltage xIO Probe
extends
measurement to 600V. Peak
voltage is 2.5x range and 375V in
250V range.
Resolution 0.1 mV, 1 mV, 0.01 V.
0.1V Multiply X10 with High Voltage
Probe.
Accuracy (AC Coupled)
Using High Voltage 10:1
Probe
Valid from 5%.. 100% of range.
50 Hz...60 Hz
±(1%+ 10)
20 Hz...20 kHz ±(2%+
15)
5HZ...1 MHz
Accuracy (DC Coupled)
Using High Voltage 10:1
Probe
±
(3% +
20)
50 Hz... 60 Hz
±
(1% +
10)
1 Hz.. .20 kHz
±
(2% +
15)
Crest Factor
Meter prevents crest factor errors
by autoranging on Input waveform
peaks.
Digital Display
3000 counts Up to 4500 counts,
at 260V range: 2500.
Display Update c 300 ms
Response Time
@ Input freq
>50
Hz
<
3.5s
SMOOTH < 10s
FAST < Is
DC Common Mods
Rejection Ratio
> 100 dB
@ dc
>
100 dB @
50, 60.
or 400 Hz
AC Common
Mode
Rejection
Ratio >60d6 @ dc..60Hz

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 93 and is the answer not in the manual?

Fluke 93 Specifications

General IconGeneral
BrandFluke
Model93
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals