Page #112 background image
DSP-4000 Series
Users Manual
4-22
Identifying Hub Port Connections
The hub port locator helps you determine which port a cable is connected to at a
hub. The locator sends a link pulse to the hub, causing the port’s LED to blink.
To identify a hub port connection, proceed as follows:
1. Attach a traffic link interface adapter (such the optional DSP-LIA013) to the
test tool.
2. Turn the rotary switch to MONITOR.
3. Use D to highlight the hub port locator selection; then press E.
4. Use a patch cable of the correct impedance to connect the test tool to the
network as directed on the display.
5. Locate the connected port by finding the flashing LED on the hub’s LED
panel.
Monitoring Impulse Noise
The Monitor Impulse Noise function allows you to monitor electrical noise on
inactive twisted pair cable. Pair 3, 6 is monitored.
The noise test takes noise voltage samples every second. Voltages that exceed the
impulse noise threshold are regarded as noise “hits.” If the 10BASE-T standard is
selected, the noise test results include a pass or fail indication. A fail result is
displayed if more than two noise hits are detected in a 10-second interval.

Table of Contents

Other manuals for Fluke CableAnalyzer DSP-4000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke CableAnalyzer DSP-4000 Series and is the answer not in the manual?

Fluke CableAnalyzer DSP-4000 Series Specifications

General IconGeneral
BrandFluke
ModelCableAnalyzer DSP-4000 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals