Page #94 background imageLoading...
Page #94 background image
DSP-4000 Series
Users Manual
4-4
Running a Single Test on Twisted Pair Cable
To run a test as a Single Test, refer to Figure 4-1 and proceed as follows:
Note
For instructions on running the HDTDR test or HDTDX analyzer,
see the later sections on those topics in this chapter.
1. Attach the appropriate link interface adapters to the main and remote units.
Refer to the table in the Appendix.
2. Turn on the remote unit.
3. Connect the remote to the far end of the cable link. For channel testing,
connect using the network equipment patch cord.
4. Turn the rotary switch on the main unit to SINGLE TEST.
5. Connect the test tool to the near end of the cable link. For channel testing,
connect using the network equipment patch cord.
6. Use U D to highlight the test you want to run.
7. Press E to start the highlighted test.
Note
If a remote is required for the test, but is not connected, the test tool
displays the message SCANNING FOR SMART REMOTE and
does not run the test until a remote is connected.
If the calibration message appears, refer to “Calibrating the Test
Tool” in Chapter 6 for complete calibration instructions.

Table of Contents

Other manuals for Fluke CableAnalyzer DSP-4000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke CableAnalyzer DSP-4000 Series and is the answer not in the manual?

Fluke CableAnalyzer DSP-4000 Series Specifications

General IconGeneral
BrandFluke
ModelCableAnalyzer DSP-4000 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals