Autotest on Coaxial Cabling (75 )
1 Turn on the tester and turn the rotary switch to
AUTOTEST.
2 Press
K c. If the coax test is disabled, press
H or J Setup to enable it.
3 Connect the tester and wiremap adapter or ID
locator to the cabling as shown in Figure 13.
4 Press
P. The Autotest proceeds when a wiremap
adapter or ID locator is detected. The analog toner
turns on if neither is detected.
5 To view results, press
J M. See Figure 14.
6 To save the results:
a. Press
K S.
b. Use
AD and H to select the Site, Location,
or Outlet field for editing. You can enter up to
17 characters in each field. See Figure 4 on page
13 for details on editing text.
To see a list of predefined labels for the
highlighted field, press
J List. Use AD,
B C, or SHIFT + AD to move through the
list. Use H or J to select an entry.
c. On the Enter ID screen, press
K S to save
the results with the Site, Location, and Outlet
entries shown.
Note
The last character of the Outlet string
increments each time you save an Autotest.