MICROSCANNER
ENGLISH - 13
activate the blinking Hub light.
The word SIGNAL blinks once every two
seconds right below the word Hub. Go to the
wiring closet to view a light that blinks once
every two seconds at the port to which the cable
is connected.
MICROSCANNER detects the kind of hub it is
connected to: 10, 100, or 10/100 alternately will
be displayed right after the word Hub. The
number is followed by the letters F and/or H as an
indication for the hub's full or half duplex capabili-
ties. Descriptions are as follows:
10 H - 10BASE-T
10 HF - 10BASE-T full duplex
100 H - 100BASE-TX
100 HF - 100BASE-T full duplex
100 HF4 - 100BASE-T full duplex, 100BASE-T4
MICROSCANNER also Identifies workstations.
1. Connect the cable to be tested to the MAIN
jack (identified on the unit right above the
modular 8 jack).
2. To display the length screen, press the
MODE key until the word LENGTH appears
on the screen. MICROSCANNER displays
the word PC followed by the length to the
PC.