MICROSCANNER
ENGLISH - 20
Test Interface:
Main: Modular 8 connector for length,
10/100 link identification, wiremap,
office identifier/room identifier, trace
Loopback: Modular 8 connector for patch cable
wiremap
Calibration: User selectable NVP
NVP calculation based on known cable length
Minimum length: 15 meters (50 feet)
Length:
Maximum length: 450 meters (1500 feet)
Office Identifier:
Maximum length: 150 meters (500 feet)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke MICROSCANNER and is the answer not in the manual?

Fluke MICROSCANNER Specifications

General IconGeneral
Length MeasurementYes
WiremapYes
Wiremap DisplayGraphical
Tone GenerationYes
Cable TypesTwisted Pair
DisplayLCD
Power SourceBattery
Fault TypesOpen, Short, Split Pair
ConnectorsRJ45