3. Product Description
Property Value Unit
Permitted relative humidity
(Non-condensing)
(Transport and storage)
5 … 95 %
Permitted temperature
(Operation)
-20 … +65 °C
Permitted relative humidity
(Non-condensing)
(Operation)
5 … 95 %
Cooling Passive -
* The specified protection class only applies if the cable connections have the same or a higher
protection class.
3.2.6 Tested Standards and MTBF
Tested Standards
Table 11: Tested Standards
Test Standard
Shock IEC 60068-2-27, 10 g in all directions
Vibration IEC 60068-2-6, 2 g
Temperature
IEC 60068-2-1 Class 3M6
IEC 60068-2-2 Class 3M6
Electromagnetic Compatibility IEC 61326-1, EN 55032
MTBF
Table 12: MTBF
Property Value Unit
MTBF > 100000 h
16 / 76