8. Troubleshooting
Table 44: Troubleshooting Profinet Status word 1
Problem Possible cause Solution
Bit 2 in
Status word 1
set.
Initializing
u
Wait until the initialization is
complete.
u
Reboot the Blackbird OECD. Turn the
power supply off and on.
Bit 3 in
Status word 1
set.
Rebooting soon
u
Wait until the reboot is complete.
Bit 4 in
Status word 1
set.
Self Diagnosis
u
Wait until the automatic
troubleshooting is complete.
u
Reboot the Blackbird OECD. Turn the
power supply off and on.
Bit 6 in
Status word 1
set.
Firmware Error
u
Reboot the Blackbird OECD. Turn the
power supply off and on.
u
Do a firmware update. See
Firmware Update via Web Interface,
page 66.
Bit 7 in
Status word 1
set.
Module Outage
Error
u
Reboot the Blackbird OECD. Turn the
power supply off and on.
Bit 8 in
Status word 1
set.
Light Source
Error
u
Reboot the Blackbird OECD. Turn the
power supply off and on.
Bit 9 in
Status word 1
set.
Temperature
Error
u
Reboot the Blackbird OECD. Turn the
power supply off and on.
u
Make sure that the temperature
regulation in the control cabinet
functions properly.
Bit 20 ... 21 in
Status word 1
set.
Error in channel n
u
Check which warnings are pending.
See Opening the Web Interface.,
page 52.