EasyManuals Logo
Home>fos4X>Measuring Instruments>Blackbird OECD MDE1195

fos4X Blackbird OECD MDE1195 User Manual

fos4X Blackbird OECD MDE1195
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #61 background imageLoading...
Page #61 background image
8. Troubleshooting
Table 44: Troubleshooting Profinet Status word 1
Problem Possible cause Solution
Bit 2 in
Status word 1
set.
Initializing
u
Wait until the initialization is
complete.
u
Reboot the Blackbird OECD. Turn the
power supply off and on.
Bit 3 in
Status word 1
set.
Rebooting soon
u
Wait until the reboot is complete.
Bit 4 in
Status word 1
set.
Self Diagnosis
u
Wait until the automatic
troubleshooting is complete.
u
Reboot the Blackbird OECD. Turn the
power supply off and on.
Bit 6 in
Status word 1
set.
Firmware Error
u
Reboot the Blackbird OECD. Turn the
power supply off and on.
u
Do a firmware update. See
Firmware Update via Web Interface,
page 66.
Bit 7 in
Status word 1
set.
Module Outage
Error
u
Reboot the Blackbird OECD. Turn the
power supply off and on.
Bit 8 in
Status word 1
set.
Light Source
Error
u
Reboot the Blackbird OECD. Turn the
power supply off and on.
Bit 9 in
Status word 1
set.
Temperature
Error
u
Reboot the Blackbird OECD. Turn the
power supply off and on.
u
Make sure that the temperature
regulation in the control cabinet
functions properly.
Bit 20 ... 21 in
Status word 1
set.
Error in channel n
u
Check which warnings are pending.
See Opening the Web Interface.,
page 52.
© fos4X 2020
MDE1195_4-10_1.3.x_5.0_Blackbird
OECD_(9CH, PRN)-en-us
61 / 76

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the fos4X Blackbird OECD MDE1195 and is the answer not in the manual?

fos4X Blackbird OECD MDE1195 Specifications

General IconGeneral
Brandfos4X
ModelBlackbird OECD MDE1195
CategoryMeasuring Instruments
LanguageEnglish