Program Code Descriptions
When a valid four digit program code has been entered, stored data or program
options will show in the displays.
The MENU and SILENCE buttons are used to change the data. The SILENCE
button will select the digit that is to be changed. The MENU button will change the
digit or change the option choice.
Data Display Codes 1000
Press the SILENCE button to exit the data display mode.
1110 - Fault Warnings
This code will show the last ten (10) fault warnings that have occurred. The RPM
display will show a fault code and the message display will alternate between showing
the date and time that the fault occurred. Press the MENU button to scroll. Refer to
Table 2. Fault Warnings
1120 - Maximum Engine RPM
This code will display the maximum RPM that the engine has attained.
Parameter Settings Codes 2000
Press the SILENCE button first then the MENU button and hold them both for 3
seconds to accept changes and exit the parameter settings mode.
2110 - Clock
This code will allow the clock display to be changed.
2120 - Date
This code will allow the date display to be changed.
2130 - Clear Fault Warnings
This code will allow the stored fault warnings and maximum RPM to be cleared
from memory. It will clear the history of all ten (10) fault warnings. Select YES or
no.
2140 - RPM Calibration
This code will allow the digits in the RPM display to be adjusted to match a
tachometer. This is for engines that do not receive RPM data over the datalink and
have the yellow RPM signal wire (pin 12 on the 12-pin connector) connected to an
RPM source.
2150 - Perform System Check
This code will allow scrolling through system status information.