PBA100 Rev0407
30
Figure 10. Navistar PBA104 Wiring
Navistar Harness Connections
Interface Information
The ECM must be programmed for a remote throttle input. Set PTO REMOTE
PEDAL to 1. (This will enable the remote throttle input.)
The VARIABLE PTO ENABLE input has to be at +12 VDC to activate the remote
throttle. (+12 VDC can be picked up from the interlock circuit.)
Note: 2004 and newer model engines with code 12VXY and the
Remote Engine Speed Controller Module (RESCM) installed.
ATA
Datalink
Connector
J1939 CAN (–)
Black Wire
Red Wire
Pin D
J1939 CAN (+)
Pin C
12-Pin
Connector
(Refer to
Figure 4)
J3 Application
I/O Connector
RPS Input (rem Accelerator)
RESCM
RVAR (Variable PTO Enable)
Vcref (Voltage Ref 5v)
RPS_RTN (Rem Accel. RTN)
J3-14
J3-19
J3-11
J3-17
8-Pin
Connector
(Refer to
Figure 5)
White Wire
GreenWire
Orange Wire
Blue Wire
Note: Refer to Figure 5. PBA 8-Pin Connector Wiring
for power and interlock wire connections.

Table of Contents

Other manuals for FRC PumpBoss PBA100

Related product manuals