PBA100 Rev0407
28
Figure 8. Cummins PBA101 Wiring
Cummins Harness Connections
Interface Information
For use on 2004 or newer engines.
The PUMP BOSS governor is designed to control engine throttle directly over the
SAE J1939 databus.
If the PUMPBOSS is being used on a COMMERCIAL CHASSIS with a Cummins
Engine, ENSURE that the Cummins Engine EMERGENCY VEHICLE CALIBRATION
is programmed in the engine ECM for the PUMP BOSS to work.
ISB, ISC, ISL, and ISM Engine Interface
J1939 Datalink (–)
Black Wire
Red Wire
J1939 Datalink (+)
47
46
12-Pin
Connecton
(Refer to
Figure 4)
ECM 50-Pin
J2 Connector
Note: Refer to Figure 5. PBA 8-Pin Connector Wiring
for power and interlock wire connections.
J1939 Datalink (–)
Black Wire
Red Wire
J1939 Datalink (+)
21
01
12-Pin
Connecton
(Refer to
Figure 4)
ECM 60-Pin
J2 Connector
2007
ISB07/ISC07/ISL07
CM 2150D Model Engines
2007
ISM07 CM 876 Model Engines
2004 to 2006
ISB02/ISC03/ISL03 CM850 Model Engines
ISM02 CM870 Model Engines