EasyManua.ls Logo

Friedrich VRPXEMWRT2 - APPENDIX 1 - Energy Saving Presets

Friedrich VRPXEMWRT2
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
49
APPENDIX 1 - Energy Saving Presets
SCREEN
NUMBER
Level
0
Level
1
Level
2
Level
3
Level
4
Level
5
1
Fan Control Mode AUTO AUTO AUTO AUTO AUTO AUTO
2
1st Stage Differential Heat 0.5 0.5 0.5 0.5 0.5 0.5
3
2nd Stage Differential Heat 1 1 1 2 2 2
4
1st Stage Differential Cool 0.5 0.5 0.5 0.5 0.5 0.5
5
Guest Occupancy Threshold
0 5 5 5 5 5
6
Night Occupancy Threshold 1 1 1 1 1 1
7
N/A
8
Night Occupancy Start 18 19 20 21 22 23
9
Night Occupancy End 12 11 10 9 8 7
10
N/A
11
N/A
12
Setback Delay - Heat 0 30 25 20 15 10
13
Minimum Setback Temperature 67 66 65 64 63 62
14
Setback Delay - Cool 0 30 25 20 15 10
15
Maximum Setback Temperature 72 74 76 78 80 82
16
N/A
17
Minimum Set point 64 64 65 66 67 68
18
Maximum Set point 82 82 80 78 76 74
19
Temperature Control Mode AUTO AUTO AUTO AUTO AUTO AUTO
20
Auto Changeover Set Point Offset (Dead Band)
1 1 1 1 1 1
21
Auto Restore OFF ON ON ON ON ON
21
Setback Set Points OFF ON ON ON ON ON
22
Automatic Humidity Control ON ON ON ON ON ON
23
Temperature Calibration 0 0 0 0 0 0
VPXEMWRT2-Thermostat Manual_pkg.indd 49 2017-12-15 3:37 PM