“OMEGA²” BOARD PROGRAMMING TABLE (**)
P DESCRIPTION
MIN MAX Chef 30 Chef 60
STEP
P1
Machine model - -
P2
Tank probe correction (TEV) -6° +6° - - 0,5°C
P3
Probe correction
fluid (TEF)
-6° +6° - - 0,5°C
P4
Probe correction
auxiliary tank (TEC)
-6° +6° - - 0,5°C
P5
Tank overtemperature compensation
when TEV>40°C
-6° +6° - - 0,5°C
P6
TEF Control Lim. in Heating mode
(excluding Tempering Cycles)
60° 122° 122° 122° 1°C
P7
Delta Lim. in C/F TEV-TEF
(Tempering Cycles only)
4° 10° 8° 8° 1°C
P8
TEF Control Lim.
(Tempering pres. only)
30° 80° 40° 40° 1°C
P9
TEF Control Lim. in Preheating mode 30° 90° 80° 30° 1°C
P10
Anti-freeze intervention temp. (on TEC)
when TEV>15°C
0° -10° -5° -5° 1°C
P11
Anti-freeze intervention temp. (on TEC)
when TEV<15°C
0° -10° -4° -4° 1°C
P12
TEF Control Lim. in heat reduction mode 98° 100° - - 1°C
P13
TEF Control Lim. in Tempering
STORAGE mode
0° 20° 8° 8° 1°C
P14
Delta TEF-TEV in step temperature
setting
0° 20° 10° 10° 1°C
P15
Anti-temperature-drift function 0° 30° 10° 10° 1°C
P16
Temperature indication on display C F C C
F=°F
C=°C
P17
LCD language selection - - ITA ITA
ITA, ING, FRA,
DEU, SPA,
CEZ
P18
FRIGOMAT logo visualisation on LCD
display
0 1 1 1
0=No logo
1=Logo
(*) These parameters vary for each unit and variant.
(**) The parameters may vary depending on the software version or customisation. You
can always refer to the test inspection board supplied with the machine.