29
EN
Check compatibility of power sources and remote
controls
Safety
Checking power
source compati-
bility
Open "Machine pre-sets" on the RCU
5000i menu
Select the "Version" screen
Check that the power source DSP soft-
ware version is 5.01.063 or higher
- If not, the power source cannot be
used for CMT Twin applications
Checking the
RCU 5000i data-
base version
WARNING! If the equipment is used or tasks are carried out incorrectly, serious
injury or damage may result. All the work described below must only be carried
out by trained and qualified personnel. Do not carry out any of the work described
below until you have fully read and understood the following documents:
- these operating instructions
- all the operating instructions for the system components, especially the safe-
ty rules
CAUTION! The power sources must be switched on for the following work. This
poses a risk of injury and material damage due to:
- welding current
- unintentional ignition of an arc
- emerging wire electrodes
Until all work is completed, ensure that:
- welding is not initiated by any power source
- the wire electrodes are not fed out
NOTE! Check the compatibility of both power sources.
1
2
3
NOTE! Check the database version of both RCU 5000i devices.