43
EN
Use the adjusting dial to select "MIG/
MAG synergic welding" from the RCU
5000i menu
Press the OK button
- The last "Data" screen called up appe-
ars
CAUTION! The power sources must be switched on for the following work. This
poses a risk of injury and material damage due to:
- welding current
- unintentional ignition of an arc
- emerging wire electrodes
Until all work is completed, ensure that:
- welding is not initiated by any power source
- the wire electrodes are not fed out
NOTE! The work described below is performed on both power sources using the
RCU 5000i.
2
3